Measuring electrodes and temperature compensators
Electrodes for pH Measurement
Order office (electrical products)+375 (232) 33-31-04+375 (232) 33-32-05
Description
ЭСЛ specifications:
ЭСП specifications:
ЭСКЛ specifications:
5М2 specifications:
Technical specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Temperature of the analysed medium
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- 0 … 40 °C
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- 25 … 100 °C
- ESЛ-45-11 · 0 … 12 рН
- 0 … 40 °C
- ESЛ-15-11 · 0 … 14 рН
- 25 … 100 °C
Pressure, of, the, analysed, medium
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- Atmospheric pressure
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- Atmospheric pressure
- ESЛ-45-11 · 0 … 12 рН
- Atmospheric pressure
- ESЛ-15-11 · 0 … 14 рН
- Atmospheric pressure
Isopotential point coordinates
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- pHi, =, 7, pH, Еу, =, -25, mV
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- pHi, =, 7, pH, Еу, =, -25, mV
- ESЛ-45-11 · 0 … 12 рН
- pHi, =, 4.25, pH, Еу, =, -25, mV
- ESЛ-15-11 · 0 … 14 рН
- pHi, =, 4.25, pH, Еу, =, -25, mV
Electrical resistance at 20 °C, Мом
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- (50 ± 40)
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- (500 ± 250)
- ESЛ-45-11 · 0 … 12 рН
- (50 ± 40)
- ESЛ-15-11 · 0 … 14 рН
- (500 ± 250)
Electrode sensing element
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- Special glass
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- Special glass
- ESЛ-45-11 · 0 … 12 рН
- Special glass
- ESЛ-15-11 · 0 … 14 рН
- Special glass
Electrode overall dimensions, maximum - diameter of the immersed electrode section - electrode length - cable length
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- 12, mm, 160, mm, 1000, mm
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- 12, mm, 160, mm, 1000, mm
- ESЛ-45-11 · 0 … 12 рН
- 8.25, mm, 130, mm, none
- ESЛ-15-11 · 0 … 14 рН
- 8.25, mm, 130, mm, none
Connector
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- №3 – ESL-43-07, ESL-63-07
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- №3 – ESL-43-07, ESL-63-07
- ESЛ-45-11 · 0 … 12 рН
- Special
- ESЛ-15-11 · 0 … 14 рН
- Special
Connector
- ESЛ-43-07 ЭСЛ-43-07СР · 0 … 12 рН
- №7 – ESL-43-07SR, ESL-63- 07СР
- ESЛ-63-07 ESЛ-63-07СР · 0 … 14 рН
- №7 – ESL-43-07SR, ESL-63- 07СР
- ESЛ-45-11 · 0 … 12 рН
- Special
- ESЛ-15-11 · 0 … 14 рН
- Special
Collapse specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Temperature of analysed medium
- ESП-01-14 · 0…14pH 250C
- 25…100 0С
- ЭСП-04-14 · 0…12pH 250C
- 0…40 0С
- ESП-31-06 · 0…11pH 800C
- 70…150 0С
Pressure, of, the, analysed, medium, Мпа
- ESП-01-14 · 0…14pH 250C
- -0.09….+0.6
- ЭСП-04-14 · 0…12pH 250C
- -0.09….+0.6
- ESП-31-06 · 0…11pH 800C
- 1.2 MPa
Coordinates of the isopotential point (code)
- ESП-01-14 · 0…14pH 250C
- рН, and, =, 4.25, pH, Э, and, =-25, mV, (code, 4)
- ЭСП-04-14 · 0…12pH 250C
- рН, and, =, 4.25, pH, Э, and, =-25, mV, (code, 4)
- ESП-31-06 · 0…11pH 800C
- рН, and, =, 1.5, pH, Э, and, =, -, 57, mV
Coordinates of the isopotential point (code)
- ESП-01-14 · 0…14pH 250C
- рНand=, 7, pH, Э, and, =, -50, mV, (code, 7)
- ЭСП-04-14 · 0…12pH 250C
- рН, and, =, 7.2, pH, Э, and, =, -20, mV, (code, 7)
- ESП-31-06 · 0…11pH 800C
- рН, and, =, 1.5, pH, Э, and, =, -, 57, mV
Coordinates of the isopotential point (code)
- ESП-01-14 · 0…14pH 250C
- pHi, =, 10, pH, Еи, =, -25, mV, (code, 10)
- ЭСП-04-14 · 0…12pH 250C
- pHi, =, 10, pH, Еи, =, -25, mV, (code, 10)
- ESП-31-06 · 0…11pH 800C
- рН, and, =, 1.5, pH, Э, and, =, -, 57, mV
Electrical resistance, Мом
- ESП-01-14 · 0…14pH 250C
- (500, ±, 250), 20, ºС
- ЭСП-04-14 · 0…12pH 250C
- (50, ±, 40), 20, ºС
- ESП-31-06 · 0…11pH 800C
- from, 5, to, 50, 70, ºС
Electrode sensing element
- ESП-01-14 · 0…14pH 250C
- Special glass
- ЭСП-04-14 · 0…12pH 250C
- Special glass
- ESП-31-06 · 0…11pH 800C
- Special glass
Electrode overall dimensions, maximum:
- ESП-01-14 · 0…14pH 250C
- —
- ЭСП-04-14 · 0…12pH 250C
- —
- ESП-31-06 · 0…11pH 800C
- —
- diameter of immersed section of electrode
- ESП-01-14 · 0…14pH 250C
- 12 mm
- ЭСП-04-14 · 0…12pH 250C
- 12 mm
- ESП-31-06 · 0…11pH 800C
- 12 mm
- electrode length
- ESП-01-14 · 0…14pH 250C
- 155 mm
- ЭСП-04-14 · 0…12pH 250C
- 155 mm
- ESП-31-06 · 0…11pH 800C
- 160 mm
- lead wire length
- ESП-01-14 · 0…14pH 250C
- For ЭСП-01-14, ЭСП-04-14: wire or cable from 200 to 3000 mm; for ЭСП-31-06: screened wire from 200 to 3000 mm. Specify the required length when ordering.
- ЭСП-04-14 · 0…12pH 250C
- For ЭСП-01-14, ЭСП-04-14: wire or cable from 200 to 3000 mm; for ЭСП-31-06: screened wire from 200 to 3000 mm. Specify the required length when ordering.
- ESП-31-06 · 0…11pH 800C
- For ЭСП-01-14, ЭСП-04-14: wire or cable from 200 to 3000 mm; for ЭСП-31-06: screened wire from 200 to 3000 mm. Specify the required length when ordering.
Connector
- ESП-01-14 · 0…14pH 250C
- No., 2, for, wire, No., 1, for, cable
- ЭСП-04-14 · 0…12pH 250C
- No., 2, for, wire, No., 1, for, cable
- ESП-31-06 · 0…11pH 800C
- №1
Expand specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Temperature of the analysed medium
- ESКЛ-08М · 0 …12 рН
- 0 … 50 ºС
- ЭСКЛ-08М.1 · 0 …12 рН
- 0 … 50 ºС
Pressure, of, the, analysed, medium
- ESКЛ-08М · 0 …12 рН
- Atmospheric pressure
- ЭСКЛ-08М.1 · 0 …12 рН
- Atmospheric pressure
Isopotential point coordinates
- ESКЛ-08М · 0 …12 рН
- pHi, =, 7, pH, Еу, =, -25, mV
- ЭСКЛ-08М.1 · 0 …12 рН
- pHi, =, 4.25, pH, Еу, =, -25, mV
Electrical resistance of measuring electrode at 20 ºС
- ESКЛ-08М · 0 …12 рН
- (50 ± 40) Moh
- ЭСКЛ-08М.1 · 0 …12 рН
- (50 ± 40) Moh
Electrical resistance of auxiliary electrode at 20 ºС, maximum
- ESКЛ-08М · 0 …12 рН
- 20 com
- ЭСКЛ-08М.1 · 0 …12 рН
- 20 com
СкКСl solution outflow rate through electrolytic junction
- ESКЛ-08М · 0 …12 рН
- 0, 3, …, 3, 5, мл, per, day
- ЭСКЛ-08М.1 · 0 …12 рН
- 0, 3, …, 3, 5, мл, per, day
Measuring electrode sensing element
- ESКЛ-08М · 0 …12 рН
- Special glass
- ЭСКЛ-08М.1 · 0 …12 рН
- Special glass
Reference electrode system
- ESКЛ-08М · 0 …12 рН
- Ag/AgCl + KCl
- ЭСКЛ-08М.1 · 0 …12 рН
- Ag/AgCl + KCl
Reference electrode electrolyte
- ESКЛ-08М · 0 …12 рН
- Saturated КСl solution
- ЭСКЛ-08М.1 · 0 …12 рН
- Saturated КСl solution
Electrode overall dimensions, maximum: - diameter of immersed electrode section including protruding electrolytic junction - electrode length - cable length
- ESКЛ-08М · 0 …12 рН
- 20, mm, 175, mm, 1000, mm
- ЭСКЛ-08М.1 · 0 …12 рН
- 20, mm, 175, mm, 1000, mm
Connector
- ESКЛ-08М · 0 …12 рН
- №7
- ЭСКЛ-08М.1 · 0 …12 рН
- №7
Expand specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Pressure, of, the, analysed, medium
- 5М2.840.019 · 10 … 50 °C
- Atmospheric pressure
- 5М2.840.074 · 10 … 50 °C
- Atmospheric pressure
Electrical resistance at 20 °C, Мом
- 5М2.840.019 · 10 … 50 °C
- (400 ± 200)
- 5М2.840.074 · 10 … 50 °C
- (200 ± 100)
Electrode sensing element
- 5М2.840.019 · 10 … 50 °C
- Special glass
- 5М2.840.074 · 10 … 50 °C
- Special glass
Electrode overall dimensions, maximum: - diameter of the immersed electrode section - electrode length
- 5М2.840.019 · 10 … 50 °C
- 7 mm 160 mm
- 5М2.840.074 · 10 … 50 °C
- 7 mm 165 mm
Connector
- 5М2.840.019 · 10 … 50 °C
- No. 6
- 5М2.840.074 · 10 … 50 °C
- No. 6
Expand specifications
Contacts
If you have any questions, you can use the following contacts:
Order office (electrical products)
Warranty service and quality department