Description
Technical specifications of the pH-150М pH meter/millivoltmeter:
Technical specifications of the pH-150МП pH meter/millivoltmeter:
Specifications of the АЖА laboratory oxygen meter:
* А — dissolved oxygen concentration, % О2 (mg/l).
Specifications of the И-02 electrode system simulator:
Specifications of the И-160МП laboratory ion meter:
Specifications of the БАТ-15.2МП automatic titration unit:
Specifications of the pNO3-07 laboratory nitrate meter:
Specifications of ШЛ laboratory stands:
Specifications of ММ magnetic stirrers:
Detailed product information is available in the catalogue.
Technical specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Hydrogen ion activity
- Unit of measurement
- рН
- Range measurement
- from, –1, 00, to, +14, 00
- Resolution
- 0,01
- Permissible limits of basic absolute error · Converter
- ±0.02
- Permissible limits of basic absolute error · Instrument
- ±0.05
Oxidation-reduction potential
- Unit of measurement
- мВ
- Range measurement
- from –1999 to +1999
- Resolution
- 1,0
- Permissible limits of basic absolute error · Converter
- ±3
- Permissible limits of basic absolute error · Instrument
- ±3
Temperature of the analysed medium
- Unit of measurement
- ºС
- Range measurement
- from –10 to +100
- Resolution
- 1,0
- Permissible limits of basic absolute error · Converter
- ±2
- Permissible limits of basic absolute error · Instrument
- ±2
Overall dimensions
- Unit of measurement
- mm
- Range measurement
- 240, x, 110, x, 75
- Resolution
- 240, x, 110, x, 75
- Permissible limits of basic absolute error · Converter
- 240, x, 110, x, 75
- Permissible limits of basic absolute error · Instrument
- 240, x, 110, x, 75
Converter weight
- Unit of measurement
- kg
- Range measurement
- 0,8
- Resolution
- 0,8
- Permissible limits of basic absolute error · Converter
- 0,8
- Permissible limits of basic absolute error · Instrument
- 0,8
Collapse specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Concentration of dissolved oxygen in water
- Unit of measurement · % O2
- mg/l
- Range measurement · from 0,0 to 199,9 from 0 to 320
- from, 0, 00, to, 19, 99, from, 0, 0, to, 30, 0
- Range measurement · 0,1 1,0
- 0,01 0,1
- Permissible basic absolute error limit · ± (2+0.01A*) ± (4+0.01A*)
- ± (0.2+0.01A*) ± (0.4+0.01A*)
Temperature of the analysed medium
- Unit of measurement · % O2
- ºС
- Range measurement · from 0,0 to 199,9 from 0 to 320
- from, 0, 0, to, 50, 0
- Range measurement · 0,1 1,0
- 0,1
- Permissible basic absolute error limit · ± (2+0.01A*) ± (4+0.01A*)
- ± 0.5
AC mains power supply
- Unit of measurement · % O2
- V/Hz
- Range measurement · from 0,0 to 199,9 from 0 to 320
- (230±22) / (50±0,5)
- Range measurement · 0,1 1,0
- (230±22) / (50±0,5)
- Permissible basic absolute error limit · ± (2+0.01A*) ± (4+0.01A*)
- (230±22) / (50±0,5)
Overall dimensions
- Unit of measurement · % O2
- mm
- Range measurement · from 0,0 to 199,9 from 0 to 320
- 245х115х75
- Range measurement · 0,1 1,0
- 245х115х75
- Permissible basic absolute error limit · ± (2+0.01A*) ± (4+0.01A*)
- 245х115х75
Weight
- Unit of measurement · % O2
- kg
- Range measurement · from 0,0 to 199,9 from 0 to 320
- 1,0
- Range measurement · 0,1 1,0
- 1,0
- Permissible basic absolute error limit · ± (2+0.01A*) ± (4+0.01A*)
- 1,0
Expand specifications
- Resistance values simulating the internal resistance of the measuring electrode (Ru), and basic relative error Ru: 0
- (500±25%) MΩ and (1000±25%) MΩ
- Resistance values simulating the internal resistance of the auxiliary electrode (RВ), and basic relative error RВ: 0
- (10±1%) кОм and (20±1%) to Om
- Simulator output voltage at Ru = RВ = 0
- no more than 0,55 кОм per 1 V of output voltage
- The basic absolute error in setting simulator output voltage D, Мв does not exceed the values defined by the formula
- D=±(0.005 Ux +0.1)
- Voltage between the auxiliary electrode circuit and the simulator's Earth terminal (Earth-solution EMF)
- – (1.5±0,2) V + (1.5±0,2) V
- Weight
- 2.5 kg
- Overall dimensions
- 250 ´ 160 ´ 145, mm
Expand specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Hydrogen ion activity and other monovalent and divalent cations and anions
- Unit of measurement
- pH (pX)
- Range measurement
- from, –20, 00, to, +20, 00
- Resolution
- 0,01
- Permissible limits of basic absolute error · Converter
- ±0,02 for monovalent ions ±0,04 for divalent ions
Oxidation-reduction potential
- Unit of measurement
- мВ
- Range measurement
- from –3000 to +2000
- Resolution
- 0,1
- Permissible limits of basic absolute error · Converter
- ±1.0
Temperature of the analysed medium
- Unit of measurement
- ºС
- Range measurement
- from –20 to +150
- Resolution
- 0,1
- Permissible limits of basic absolute error · Converter
- ±0.5
AC mains power supply
- Unit of measurement
- V/Hz
- Range measurement
- (230±22) / (50±0,5)
- Resolution
- (230±22) / (50±0,5)
- Permissible limits of basic absolute error · Converter
- (230±22) / (50±0,5)
Overall dimensions
- Unit of measurement
- mm
- Range measurement
- 230, x, 220, x, 85
- Resolution
- 230, x, 220, x, 85
- Permissible limits of basic absolute error · Converter
- 230, x, 220, x, 85
Converter weight
- Unit of measurement
- kg
- Range measurement
- 2,0
- Resolution
- 2,0
- Permissible limits of basic absolute error · Converter
- 2,0
Expand specifications
- Titration endpoint setting range
- from 0,0 to ± 20,0 pX; from 0,0 to ± 2000.0 mV
- Pulse solution delivery zone setting range
- from 0,000 to ± 20,000 pX, from 0,0 to ± 2000,0 mV
- Titration endpoint hold time setting range
- from 0,00 to 200,00 s
- Basic absolute error limit for titration endpoint voltage setting, referred to the instrument input
- no more than ± 3 mV in the titration endpoint setting range from 0,0 to ± 20,0 pX; from 0,0 to ± 2000.0 mV
- Basic relative titration error limit for the instrument used with a pX meter and microburette
- does not exceed ± 1 %
- Instrument AC mains supply voltage and frequency
- (230 ± 22) V (50±0.5) Hz
- Instrument power consumption
- 20 V×А.
- Instrument overall dimensions
- 210 x 160 x 80 mm
- Instrument weight
- no more than 1 kg
Expand specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Ion concentration (Сх mode)
- Unit of measurement · рNO3
- g/kg
- Indication range converter · From 0,35 to 4,70
- From, 1∙10-4, to, 99, 9
- Measurement range nitrate meter · From 0,35 to 4,70
- From, 1∙10-4, to, 99, 9
Electrode system EMF (Е mode)
- Unit of measurement · рNO3
- мВ
- Indication range converter · From 0,35 to 4,70
- From, 0, 0, to, 999, 0
- Measurement range nitrate meter · From 0,35 to 4,70
- -
Temperature of the analysed medium (t mode)
- Unit of measurement · рNO3
- °С
- Indication range converter · From 0,35 to 4,70
- From, 5, 0, to, 50, 0
- Measurement range nitrate meter · From 0,35 to 4,70
- From, 5, 0, to, 50, 0
Expand specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Diameter of mounted sensors
- ШЛ-96 · up to 5
- 6, 7.5, 8, 8.5, 11, 11.5, 12mm
- ШЛ-98 · -
- -
- ШЛ-98.1 · -
- -
- ШЛ-106 · up to 2
- 6, 7.5, 8, 8.5, 11, 11.5, 12mm
Overall dimensions, mm
- ШЛ-96 · up to 5
- from, 70, to, 500, Ø152
- ШЛ-98 · -
- 210х150х815
- ШЛ-98.1 · -
- 210x150x530
- ШЛ-106 · up to 2
- 210х150х530
Weight, kg
- ШЛ-96 · up to 5
- 2,5
- ШЛ-98 · -
- 5,5
- ШЛ-98.1 · -
- 4,0
- ШЛ-106 · up to 2
- 4,0
Expand specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Power consumption, В·А, maximum
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 5,5
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 5,5
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 7
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 200
- —
- —
Power consumption, В·А, maximum
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 5,5
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 5,5
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 7
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 200
- —
- —
Stepless, rotation, speed, control, rpm
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- From 200 to 400
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- From 200 to 400
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- From 200 to 400
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- From 200 to 400
- —
- —
Maximum, stirred, liquid, volume, л
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 0,25
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 0,25
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 3
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 3
- —
- —
Support plate temperature, ºС
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- -
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- -
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- -
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- up to 110
- —
- —
Overall dimensions, mm
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- Activator 105х95х65
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- Activator 105х95х65
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 200х180х75
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 190х195х95
- —
- —
Overall dimensions, mm
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- Power supply unit 105х55х80
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- Power supply unit 105х55х80
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 200х180х75
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 190х195х95
- —
- —
Weight, кг, maximum
- MM-01 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 1,0 (activator + power supply unit)
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 1,0 (activator + power supply unit)
- MM-02 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 1,6
- MM-03 · AC mains supply: (220±22) V, frequency (50±0,5) Hz
- 3
- —
- —
Expand specifications
Contacts
If you have any questions, you can use the following contacts:
Order office (electrical products)