← Back to category
1 / 2
Measuring electrodes and temperature compensators
Redox Electrodes for ORP Measurement
Order office (electrical products)+375 (232) 33-31-04+375 (232) 33-32-05
Description
ЭПВ, ЭПЛ technical parameters:
ЭТП specifications:
ЭО specifications:
Technical specifications
Technical specifications table: Technical specifications. The table is wider than the screen — scroll horizontally.
Pressure, of, the, analysed, medium
- ЭPВ-1 · 0 … 150 ºС
- Up, to, 1, 2, Мпа
- ЭPВ-1CP · 0 … 150 ºС
- Up, to, 1, 2, Мпа
- ЭPЛ-02 · 0 … 100 ºС
- Atmospheric pressure
Electrical resistance at 20 ºС
- ЭPВ-1 · 0 … 150 ºС
- No, more, than, 1, Ω
- ЭPВ-1CP · 0 … 150 ºС
- No, more, than, 1, Ω
- ЭPЛ-02 · 0 … 100 ºС
- No, more, than, 1, Ω
Electrode sensing element
- ЭPВ-1 · 0 … 150 ºС
- Platinum
- ЭPВ-1CP · 0 … 150 ºС
- Platinum
- ЭPЛ-02 · 0 … 100 ºС
- Platinum
Housing material
- ЭPВ-1 · 0 … 150 ºС
- Glass
- ЭPВ-1CP · 0 … 150 ºС
- Glass
- ЭPЛ-02 · 0 … 100 ºС
- Glass
Electrode overall dimensions, maximum: - diameter of the immersed electrode section - electrode length - wire length, specified when ordering
- ЭPВ-1 · 0 … 150 ºС
- 12, mm, 155, mm, 150, …, 3000, mm
- ЭPВ-1CP · 0 … 150 ºС
- 12, mm, 155, mm, 150, …, 3000, mm
- ЭPЛ-02 · 0 … 100 ºС
- 8.25, mm, 130, mm, none
Connector
- ЭPВ-1 · 0 … 150 ºС
- №2
- ЭPВ-1CP · 0 … 150 ºС
- №7
- ЭPЛ-02 · 0 … 100 ºС
- Special
Collapse specifications
- Parameter
- ETП-02
- Temperature of the analysed medium
- 0 … 100 ºС
- Pressure of the analysed medium
- Atmospheric pressure
- Electrical resistance at 20 ºС
- No more than 1 кОм
- Electrode sensing element
- Finely dispersed platinum
- Housing material
- Glass
- Electrode overall dimensions, maximum: - diameter of the immersed electrode section - electrode length - wire length
- 12 mm 155 mm 1000 mm
- Connector
- №2
Expand specifications
- Parameter
- ЭО-01
- Temperature of the analysed medium
- 0 … 60 ºС for direct measurements, 0 … 90 ºС for potentiometric titration
- Pressure of the analysed medium
- Atmospheric pressure
- Electrical resistance at 20 ºС, кОм
- 30 … 5000
- Electrode sensing element
- Special glass
- Housing material
- Glass
- Electrode overall dimensions, maximum: - diameter of the immersed electrode section - electrode length - wire length, specified when ordering
- 12 mm 155 mm 200 … 3000 mm
- Connector
- №2
Expand specifications
Contacts
If you have any questions, you can use the following contacts:
Order office (electrical products)
Warranty service and quality department